{"id":9440,"date":"2026-11-01T17:00:51","date_gmt":"2026-11-01T17:00:51","guid":{"rendered":"https:\/\/www.westernoptronics.com\/?p=9440"},"modified":"2026-11-01T17:00:51","modified_gmt":"2026-11-01T17:00:51","slug":"elsfp-connector-acceptance-inspection-return-loss","status":"publish","type":"post","link":"https:\/\/www.westernoptronics.com\/ar\/elsfp-connector-acceptance-inspection-return-loss\/","title":{"rendered":"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss"},"content":{"rendered":"<article id=\"we-connector-acceptance\">\n<style>\n#we-connector-acceptance{max-width:960px;margin:0 auto;color:#30464d;font:18px\/1.8 \"Trebuchet MS\",Verdana,sans-serif}#we-connector-acceptance *{box-sizing:border-box}#we-connector-acceptance .reading{max-width:780px;margin:auto}#we-connector-acceptance .eyebrow{font-size:13px;letter-spacing:.12em;color:#08726a;font-weight:bold;text-transform:uppercase}#we-connector-acceptance .lead{font-size:23px;line-height:1.55;color:#17343d}#we-connector-acceptance h2{font-size:30px;line-height:1.3;color:#17343d;margin:2em 0 .65em}#we-connector-acceptance h3{font-size:22px;color:#17343d}#we-connector-acceptance a{color:#08726a;text-decoration:underline;text-underline-offset:3px}#we-connector-acceptance figure{margin:32px auto;max-width:680px}#we-connector-acceptance svg{display:block;width:100%;height:auto}#we-connector-acceptance figcaption{font-size:15px;line-height:1.6;margin-top:12px;color:#52676f}#we-connector-acceptance li{margin:.65em 0}#we-connector-acceptance .note{border-left:4px solid #08726a;background:#f2f7f5;padding:18px 22px}#we-connector-acceptance .table-wrap{overflow-x:auto}#we-connector-acceptance table{border-collapse:collapse;width:100%;font-size:16px;line-height:1.6}#we-connector-acceptance th,#we-connector-acceptance td{padding:14px 12px;border-bottom:1px solid #cddedb;text-align:left;vertical-align:top}#we-connector-acceptance th{background:#edf5f2;color:#17343d}#we-connector-acceptance .closing{border-top:2px solid #08726a;margin-top:36px;padding-top:18px}#we-connector-acceptance .sources{font-size:15px}@media(max-width:600px){#we-connector-acceptance{font-size:17px}#we-connector-acceptance .lead{font-size:20px}#we-connector-acceptance h2{font-size:26px}#we-connector-acceptance th,#we-connector-acceptance td{font-size:14px;padding:10px 8px}}\n<\/style>\n<div class=\"reading\">\n<p class=\"eyebrow\">WE \/ Western Optronics \u2022 Optical Engineering<\/p>\n<p class=\"lead\">What evidence should an ELSFP buyer request before accepting the optical connection to a CPO engine?<\/p>\n<p>Ask for three separate records: end-face inspection, forward-path insertion loss, and reflected-power performance. A clean-looking connector cannot answer all three questions. Neither can a single power reading taken at an unspecified point.<\/p>\n<p>This engineering note proposes a practical acceptance worksheet for external-laser paths in AI data-center systems. It is not a test report, a universal acceptance limit, or evidence that a particular Western Optronics product has passed these tests.<\/p>\n<\/div>\n<figure><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 680 720\" role=\"img\" aria-labelledby=\"title desc\"><title id=\"title\">ELSFP connector acceptance: three separate kinds of evidence<\/title><desc id=\"desc\">Forward light passes from the external laser across a defined connector and fiber path to the optical engine. Reflected light travels back toward the source. End-face inspection, insertion loss and return loss answer different acceptance questions.<\/desc><rect width=\"680\" height=\"720\" rx=\"12\" fill=\"#f1f6f5\"\/><g font-family=\"Arial,sans-serif\" fill=\"#153b43\"><text x=\"36\" y=\"46\" font-size=\"17\" letter-spacing=\"2\">WESTERN OPTRONICS \/ ENGINEERING NOTE<\/text><text x=\"36\" y=\"91\" font-size=\"29\" font-weight=\"bold\">Three checks. Three different questions.<\/text><rect x=\"190\" y=\"125\" width=\"300\" height=\"74\" rx=\"8\" fill=\"#163e48\"\/><text x=\"340\" y=\"158\" fill=\"white\" font-size=\"24\" text-anchor=\"middle\">External CW laser<\/text><text x=\"340\" y=\"183\" fill=\"#cce8e2\" font-size=\"18\" text-anchor=\"middle\">ELSFP module<\/text><path d=\"M285 199V249\" fill=\"none\" stroke=\"#007f72\" stroke-width=\"6\"\/><path d=\"M276 238L285 253L294 238\" fill=\"none\" stroke=\"#007f72\" stroke-width=\"5\"\/><text x=\"34\" y=\"232\" font-size=\"20\">Forward power<\/text><rect x=\"190\" y=\"261\" width=\"300\" height=\"102\" rx=\"8\" fill=\"white\" stroke=\"#007f72\" stroke-width=\"2\"\/><text x=\"340\" y=\"293\" text-anchor=\"middle\" font-size=\"23\" font-weight=\"bold\">Connector + fiber path<\/text><text x=\"340\" y=\"322\" text-anchor=\"middle\" font-size=\"19\">Mark both measurement planes<\/text><text x=\"340\" y=\"346\" text-anchor=\"middle\" font-size=\"18\">Record fixtures and terminations<\/text><path d=\"M285 363V413\" fill=\"none\" stroke=\"#007f72\" stroke-width=\"6\"\/><path d=\"M276 402L285 417L294 402\" fill=\"none\" stroke=\"#007f72\" stroke-width=\"5\"\/><rect x=\"190\" y=\"425\" width=\"300\" height=\"70\" rx=\"8\" fill=\"#163e48\"\/><text x=\"340\" y=\"467\" fill=\"white\" font-size=\"24\" text-anchor=\"middle\">Optical-engine input<\/text><path d=\"M415 263V208\" fill=\"none\" stroke=\"#a86b21\" stroke-width=\"4\"\/><path d=\"M407 221L415 207L423 221\" fill=\"none\" stroke=\"#a86b21\" stroke-width=\"4\"\/><text x=\"490\" y=\"228\" font-size=\"18\">Returned light<\/text><line x1=\"36\" y1=\"530\" x2=\"644\" y2=\"530\" stroke=\"#bfd3ce\"\/><g font-size=\"21\"><text x=\"36\" y=\"572\" font-weight=\"bold\">Inspection<\/text><text x=\"234\" y=\"572\">What is on the end face?<\/text><text x=\"36\" y=\"613\" font-weight=\"bold\">Insertion loss<\/text><text x=\"234\" y=\"613\">How much forward power is lost?<\/text><text x=\"36\" y=\"654\" font-weight=\"bold\">Return loss<\/text><text x=\"234\" y=\"654\">How much power comes back?<\/text><\/g><text x=\"36\" y=\"695\" font-size=\"16\" fill=\"#526d73\">Original conceptual diagram \u2022 not a product drawing or measured result<\/text><\/g><\/svg><figcaption>Figure 1. Original conceptual diagram: forward and returned optical power answer different questions. The measurement path must be identified before results can be compared. Not a physical connector drawing or measured result. Diagram text is also explained below.<\/figcaption><\/figure>\n<div class=\"reading\">\n<h2>Start with the interface, not a generic connector limit<\/h2>\n<p>OIF&#8217;s current implementation-agreement directory lists <a href=\"https:\/\/www.oiforum.com\/technical-work\/implementation-agreements-ias\/\">OIF-ELSFP-02.0, January 2025<\/a>. ELSFP supplies continuous-wave light to optical engines; that light-delivery path is different from the engine&#8217;s modulated data output. For a refresher, see <a href=\"https:\/\/www.westernoptronics.com\/ar\/what-does-elsfp-do-in-cpo-system\/\">what an ELSFP does in a CPO system<\/a>.<\/p>\n<p>The <a href=\"https:\/\/www.oiforum.com\/wp-content\/uploads\/OIF-ELSFP-02.0-1.pdf\">ELSFP agreement<\/a> assigns several optical requirements, including tolerance to back-reflection, to the relevant optical-engine\/CPO application specification (\u00a73.4). Its defined test point TPL2 uses a characterized test-grade patch cord (\u00a73.6.1). A supplier&#8217;s module-output figure and your engine-input result therefore need a documented relationship; do not assume they describe the same boundary.<\/p>\n<h2>Keep three acceptance questions separate<\/h2>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Evidence<\/th>\n<th scope=\"col\">What it answers<\/th>\n<th scope=\"col\">What it does not prove<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">End-face image and inspection result<\/th>\n<td>What contamination or defects were observed under the stated inspection method.<\/td>\n<td>Forward transmission, return loss, or system compatibility.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Insertion loss<\/th>\n<td>How much forward optical power is lost across the defined path and fixtures.<\/td>\n<td>How much reflected light reaches the source.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Return loss \/ reflected-power result<\/th>\n<td>How much power returns toward the measurement reference plane.<\/td>\n<td>That every channel supplies adequate power to its engine.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/64254\">IEC 61300-3-35:2022<\/a> addresses visual examination of fiber-optic connector end faces. Its public scope explicitly separates visual inspection from attenuation and return-loss qualification. After the prescribed inspection and cleaning process, an inspection failure alone is not sufficient to reject a connector when specified optical performance is met. This does not justify leaving loose contamination in place. Apply the correct procedure and the agreed acceptance specification, rather than treating a microscope screenshot as the whole decision.<\/p>\n<p><a href=\"https:\/\/www.flukenetworks.com\/edocs\/white-paper-standard-compliant-certification-amp-best-practices\">Fluke Networks&#8217; inspection guidance<\/a> recommends inspection before connection and reinspection after necessary cleaning, including equipment ports. A protective cap does not establish cleanliness. For an ELSFP blind-mate interface, obtain the connector manufacturer&#8217;s approved access, inspection and cleaning procedure rather than improvising with a generic probe.<\/p>\n<p>ELSFP permits physical-contact and air-gap interface designs. Confirm which is supplied before applying a contact-ferrule inspection rule or cleaning method.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/5247\">IEC 61300-3-6<\/a> defines return loss using incident power divided by reflected power, in decibels. With this positive return-loss convention, a larger number means less returned power. A negative-dB reflectance figure uses a different sign convention; label the metric before comparing limits.<\/p>\n<h2>Make two supplier reports comparable<\/h2>\n<p>The following is a proposed procurement worksheet, not a standard-mandated form. Ask both suppliers to fill it out before comparing their pass\/fail summaries.<\/p>\n<ol>\n<li><strong>Identify the exact assembly.<\/strong> Record module and cable part numbers, revisions, serial numbers, connector geometry and channel map. A result for a different harness is supporting background, not acceptance of the delivered one.<\/li>\n<li><strong>Draw the measurement boundaries.<\/strong> Show the launch reference plane, receive plane, included mating interfaces, adapters and any fan-out. State which fixture contributions are included or removed and how that correction was established.<\/li>\n<li><strong>State conditions.<\/strong> Record wavelength, channel, source operating condition, temperature and relevant polarization state. Preserve the test setup identifier so a retest can use the same conditions.<\/li>\n<li><strong>Keep transmission and reflection results distinct.<\/strong> Request insertion loss and return loss as separate fields with units and sign convention. Identify whether the return measurement represents one interface or the complete tested assembly.<\/li>\n<li><strong>Record instrument limits.<\/strong> Include instrument model, calibration status, power range, reference method and uncertainty. A marginal result deserves review against uncertainty, not extra displayed decimal places.<\/li>\n<li><strong>Attach the decision rule.<\/strong> Cite the agreed application requirement, revision, limit and treatment of uncertainty. Leave a criterion unresolved if the engine supplier has not provided it; do not fill the gap with an unrelated connector datasheet.<\/li>\n<\/ol>\n<h2>A small example: equal loss, different evidence<\/h2>\n<p class=\"note\"><strong>Illustrative scenario only.<\/strong> Two harness reports each show 0.8 dB insertion loss. Report A includes the launch adapter and two mated interfaces; Report B excludes the launch adapter and includes one interface. The numbers are not a like-for-like comparison. Neither number reveals the return loss. No pass threshold or product performance is implied by this example.<\/p>\n<p>A useful response is to request the missing setup drawings and raw channel results, then agree on a common boundary or an explicitly documented correction. Do not average dissimilar paths to create a reassuring fleet-level number. In a multi-fiber assembly, retain results by channel so one weak path is not hidden by the mean.<\/p>\n<p>This acceptance evidence complements the <a href=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-optical-engine-power-budget\/\">engine-input power budget<\/a> and <a href=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-interface-qualification-fiber-mapping-polarization\/\">fiber-mapping and polarization checks<\/a>; it does not replace them.<\/p>\n<h2>Define the hold point before energizing the system<\/h2>\n<p>Appendix B of <a href=\"https:\/\/www.oiforum.com\/wp-content\/uploads\/OIF-ELSFP-02.0-1.pdf\">OIF-ELSFP-02.0<\/a> discusses contamination and link-loss verification before full-power operation. Inspection and cleaning alone do not assure a contamination-free connection. Use the actual system safety procedure and approved instrumentation; this article is not a live-laser handling procedure.<\/p>\n<p>For a purchasing specification, name the person or team authorized to release the assembly for system evaluation. Require traceable records, a documented disposition for inconsistent results, and a repeat-test rule after a connector, fixture or harness changes. These are proposed controls to keep an acceptance decision reproducible, not a claim of certification.<\/p>\n<div class=\"closing\">\n<h2>Build the evidence request around your CPO platform<\/h2>\n<p>Use the <a href=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-selection-guide\/\">ELSFP selection guide<\/a> to organize the application requirements and the <a href=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-evaluation-kit\/\">evaluation-kit page<\/a> to frame the intended trial. When asking about the <a href=\"https:\/\/www.westernoptronics.com\/ar\/product\/cy-elsfp-8pmf-uhp1-cwdm4-b-2xfr4-cpo-laser\/\">CWDM4 ELSFP<\/a> or <a href=\"https:\/\/www.westernoptronics.com\/ar\/product\/cy-elsfp-8pmf-uhp1-1311-b-elsfp-cw-laser-cpo\/\">1311 nm ELSFP<\/a>, specify your connector, channel map, measurement boundary and engine requirements.<\/p>\n<p><a href=\"https:\/\/www.westernoptronics.com\/ar\/contact\/\">Contact Western Optronics<\/a> to discuss the evidence needed for your evaluation. Model-specific test availability and platform compatibility must be confirmed separately.<\/p>\n<\/div>\n<p class=\"sources\"><strong>Source and scope note:<\/strong> Official OIF and IEC public materials and Fluke Networks guidance checked November 1, 2026. References support the distinctions above; the worksheet, conceptual diagram and example are original analysis. No third-party endorsement, system qualification or measured Western Optronics result is claimed.<\/p>\n<\/div>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Build an ELSFP connector acceptance plan with separate inspection, insertion-loss and return-loss evidence, defined measurement boundaries and a supplier checklist.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[143],"tags":[],"class_list":["post-9440","post","type-post","status-publish","format-standard","hentry","category-optical-engineering"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-connector-acceptance-inspection-return-loss\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS\" \/>\n<meta property=\"og:description\" content=\"Build an ELSFP connector acceptance plan with separate inspection, insertion-loss and return-loss evidence, defined measurement boundaries and a supplier checklist.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.westernoptronics.com\/ar\/elsfp-connector-acceptance-inspection-return-loss\/\" \/>\n<meta property=\"og:site_name\" content=\"WESTERN OPTRONICS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-01T17:00:51+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/\",\"url\":\"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/\",\"name\":\"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS\",\"isPartOf\":{\"@id\":\"https:\/\/www.westernoptronics.com\/#website\"},\"datePublished\":\"2026-11-01T17:00:51+00:00\",\"author\":{\"@id\":\"https:\/\/www.westernoptronics.com\/#\/schema\/person\/682bd964e801f67af5e0daa5205bcfd0\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.westernoptronics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.westernoptronics.com\/#website\",\"url\":\"https:\/\/www.westernoptronics.com\/\",\"name\":\"Western Optronics\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.westernoptronics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.westernoptronics.com\/#\/schema\/person\/682bd964e801f67af5e0daa5205bcfd0\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\/\/www.westernoptronics.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/12102b5b85b147ae700967f022c3225fece9ff92ffac16e2d8b8d2ba75e6b453?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/12102b5b85b147ae700967f022c3225fece9ff92ffac16e2d8b8d2ba75e6b453?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\/\/westernoptronics.com\"],\"url\":\"https:\/\/www.westernoptronics.com\/ar\/author\/saleswesternoptronics-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.westernoptronics.com\/ar\/elsfp-connector-acceptance-inspection-return-loss\/","og_locale":"ar_AR","og_type":"article","og_title":"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS","og_description":"Build an ELSFP connector acceptance plan with separate inspection, insertion-loss and return-loss evidence, defined measurement boundaries and a supplier checklist.","og_url":"https:\/\/www.westernoptronics.com\/ar\/elsfp-connector-acceptance-inspection-return-loss\/","og_site_name":"WESTERN OPTRONICS","article_published_time":"2026-11-01T17:00:51+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"admin","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"6 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/","url":"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/","name":"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss - WESTERN OPTRONICS","isPartOf":{"@id":"https:\/\/www.westernoptronics.com\/#website"},"datePublished":"2026-11-01T17:00:51+00:00","author":{"@id":"https:\/\/www.westernoptronics.com\/#\/schema\/person\/682bd964e801f67af5e0daa5205bcfd0"},"breadcrumb":{"@id":"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.westernoptronics.com\/elsfp-connector-acceptance-inspection-return-loss\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.westernoptronics.com\/"},{"@type":"ListItem","position":2,"name":"ELSFP Connector Acceptance: Inspection, Insertion Loss and Return Loss"}]},{"@type":"WebSite","@id":"https:\/\/www.westernoptronics.com\/#website","url":"https:\/\/www.westernoptronics.com\/","name":"Western Optronics","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.westernoptronics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Person","@id":"https:\/\/www.westernoptronics.com\/#\/schema\/person\/682bd964e801f67af5e0daa5205bcfd0","name":"admin","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/www.westernoptronics.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/12102b5b85b147ae700967f022c3225fece9ff92ffac16e2d8b8d2ba75e6b453?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/12102b5b85b147ae700967f022c3225fece9ff92ffac16e2d8b8d2ba75e6b453?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/westernoptronics.com"],"url":"https:\/\/www.westernoptronics.com\/ar\/author\/saleswesternoptronics-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/posts\/9440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/comments?post=9440"}],"version-history":[{"count":2,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/posts\/9440\/revisions"}],"predecessor-version":[{"id":9442,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/posts\/9440\/revisions\/9442"}],"wp:attachment":[{"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/media?parent=9440"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/categories?post=9440"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.westernoptronics.com\/ar\/wp-json\/wp\/v2\/tags?post=9440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}